Standard
[IEC 61000-4-2 Ed.3] What is the minimum number of surfaces on which indirect discharge must be performed?
For VCP, peripheral equipment is installed to the left, right, front, and rear of the EUT, so application to at least four surfaces is required. For HCP, the electric field is considered to extend upward from the table surface and to be nearly ...
What is a wearable device as described in IEC 61000-4-2 Ed.3?
Regardless of product size, any product used in close contact with human skin is treated as a wearable device. This concept is also explicitly stated in the standard.
For indirect discharge with power supplied under ISO10605 Ed.2, the standard states that the discharge gun ground cable should be connected to either the HCP or GRP. Which should it be connected to?
Select the connection point according to the DUT. In the standard, HCP simulates the chassis and GRP simulates the ground. If the DUT is grounded to the chassis, connect to HCP; if it is grounded to the ground, connect to GRP.
IEC 61000-4-2 requires 6kV for contact discharge at the specified test levels. Why is there no 6kV requirement for air discharge?
For contact discharge, the test voltage and peak current have a linear proportional relationship; however, for air discharge, as the test voltage increases, the peak current reaches a plateau, 2kV⇒4kV⇒8kV⇒15kV, thereby establishing relationships of 2 ...
Is it acceptable to use the insulating support (03-00066A) under ISO10605 ED.3?
The insulating support is a product corresponding to the “insulating support” in ISO10605 Ed.2. In ISO10605 Ed.3, the description of insulating support was removed and all instances were replaced with “insulating block.” * Our model number: 03-00054A ...
For electronic component testing (without power supply) under ISO10605 Ed.3, is it acceptable to perform the test using an electrostatic dissipative mat with the insulating support (model: 03-00066A)?
No. A conductive mat (model: 03-00055A) must be used. According to ISO10605 Ed.3, the electrostatic dissipative mat is specified as follows: - Height between 2 mm and 3 mm - Material having a surface resistivity between 10 MΩ and 1000 MΩ per square ...
IEC 61000-4-2 states that “the preferred test method is the contact discharge method, and the air discharge method is used when the contact discharge method cannot be applied.” Specifically, how should this be determined?
<Contact discharge> For general electronic equipment, contact discharge testing is performed on screws used to fasten the enclosure, metal parts of a metal enclosure (using a conical tip to pierce the coating and make contact with the metal), and ...
For electrostatic discharge testing, why do the standards connect the return cable to the ground plane? Is there any difference in test results between connecting it to the discharge gun holder GND terminal and performing the test?
First, regarding the mechanism of the electrostatic discharge tester and return cable, the method applies electrostatic discharge by creating a loop with the point connected by the return cable as the reference potential (0 V). The reason for ...
For the test environment when performing an electrostatic discharge test according to ISO10605, the ground plane (03-00007A) is a set of three sheets. Is it acceptable to use only one sheet?
ISO10605 does not specify the size of the ground plane. * IEC61000-4-2 states “50 cm or more on each side beyond the horizontal coupling plane.” Therefore, even an environment using only one ground plane sheet is acceptable under the ISO standard.
Probe Stand MODEL: 03-00108A is marked as “not covered by IEC standards.” Does this mean that standards-compliant testing cannot be performed using this product?
In IEC 61000-4-2 testing, the general rule is that the gun is held by a person by hand during the test. Therefore, testing with a fixed stand or robot, including ZAP (automatic electrostatic discharge application system), is outside the standard. (In ...
What is included in the test result report?
The test result report includes the test conditions and test results. Specifically, it contains the following: Purpose and overview of the test Details of the test object Test environment conditions Details of the test procedure Classification and ...
What are the details of the test procedure?
The test procedure is performed as follows to accurately evaluate the effects of electrostatic discharge: Direct discharge test: Contact discharge and air discharge are performed. Contact discharge is performed by directly touching the tip of the ...
How is the tester setup performed?
The tester setup is specified in detail, including the placement and connection method of the test object. The following are examples of a typical setup: Tabletop equipment: A wooden table 0.8 m high is placed on the ground plane, and a horizontal ...
How are the test environment conditions set?
The test environment conditions are strictly set so that they do not affect the test results. Specifically, they are as follows: Ambient temperature: 15°C to 35°C Relative humidity: 30% to 60% Atmospheric pressure: 86 kPa (860 mbar) to 106 kPa (1060 ...
How are the test results classified?
The test results are classified as follows based on the reaction of the electronic equipment to electrostatic discharge: Normal operation within the specification range: The electronic equipment continues to operate normally even when electrostatic ...
How is the test procedure performed?
The test procedure is strictly defined to accurately evaluate the effects of electrostatic discharge. Specifically, it is as follows: Direct discharge test: Contact discharge and air discharge are performed. Contact discharge is performed by directly ...
What are the specifications of the tester?
The tester specifications are designed to accurately simulate electrostatic discharge. The main specifications are as follows: Energy storage capacitance: 150 pF Discharge resistance: 330 Ω Output voltage: Contact discharge 8 kV, air discharge 15 kV ...
What types of test levels are there?
The test levels are set according to the intensity of electrostatic discharge. Specifically, they are as follows: Level 1: Contact discharge 2 kV, air discharge 2 kV Level 2: Contact discharge 4 kV, air discharge 4 kV Level 3: Contact discharge 6 kV, ...
What is the purpose of the test?
The purpose of the test is to evaluate the effects of electrostatic discharge on electronic equipment and confirm immunity to prevent malfunctions and failures. This improves product reliability and helps ensure user safety.
What is the IEC 61000-4-2 electrostatic discharge test?
The IEC 61000-4-2 electrostatic discharge test evaluates how resistant electronic equipment is to electrostatic discharge (ESD). Electrostatic discharge is likely to occur when chemical-fiber carpets or clothing are used in dry environments, and when ...
Please tell me how to return from remote control to manual operation for the ESS-S3011A.
STOP key long press returns to manual operation. (Reviewer: Nezu-san)
How long does it take to fully charge the ESS-PS1 battery from a completely discharged state?
When charging only with the power OFF, it takes 3 hours (reference value). Of course, if you use it in a way such as testing while charging the battery with AC adapter power, the time will vary depending on usage.
What does the test using the coupling plane in ISO 10605_2008 Annex F simulate?
ISO 10605_2008 Annex F assumes electrostatic discharge testing for cases where operation is performed from inside the vehicle. The expected path of static electricity is: passenger inside the vehicle (discharge gun) → DUT → vehicle body → passenger ...
When testing a DC-driven EUT in a tabletop equipment test according to IEC61000-4-2, should the AC adapter or battery be placed on the tabletop or the ground plane?
The IEC61000-4-2 standard does not specify where to place it. If placed on the tabletop, the battery is also considered part of the test subject, so it is preferable to place it on the ground plane. Since it is a DC-driven EUT, please make sure to ...
ISO10605 Ed.3 / 6.4 Ground plane states: [When aluminum is used for the ground plane, care shall be taken to ensure that oxidation does not prevent a good ground connection.] How should the aluminum plate used during testing be maintained?
We do not have specific expertise on this matter. However, because high-frequency noise such as ESD can be expected to flow as surface current rather than through the interior of the ground plane or horizontal coupling plane, surface corrosion may ...
What do the capacitor and discharge resistance combinations in ISO 10605 assume?
The capacitor and discharge resistance combinations assume the following: ○150pF-330Ω: Products that automotive technicians repair or replace parts from outside the vehicle using metal tools ○150pF-2kΩ: Products that people might touch directly with ...
What does the capacitor and discharge resistance (150pF-330Ω) in IEC 61000-4-2 assume?
It assumes the ESD phenomenon from a charged human body to electronic equipment. 150pF: Capacitance between the human body and the floor 330Ω: Human body touching with a metal object
What is the human body capacitance in electrostatic discharge testing?
The human body capacitance is considered to be approximately 100pF, and the resistance is approximately 2kΩ. IEC 61000-4-2 specifies the human body capacitance as 150pF with a margin.
What is an electrostatic discharge test?
This is a test that simulates electrostatic discharge from the human body and evaluates the resistance of electronic equipment. The actual electrostatic discharge phenomenon is air discharge, but due to poor reproducibility, contact discharge testing ...