What does the test using the coupling plane in ISO 10605_2008 Annex F simulate?

What does the test using the coupling plane in ISO 10605_2008 Annex F simulate?

ISO 10605_2008 Annex F assumes electrostatic discharge testing for cases where operation is performed from inside the vehicle.

The expected path of static electricity is: passenger inside the vehicle (discharge gun) → DUT → vehicle body → passenger inside the vehicle (discharge gun return).
Since the HCP simulates the vehicle body, to create the above loop, the discharge gun return is connected to the HCP (Horizontal Coupling Plane).