Product Specifications (including optional items)
[Option] What is the difference between the new discharge gun fixing base (03-00128A) and the old discharge gun fixing base (03-00061B)?
The discharge guns that can be mounted are different. 03-00128A: Both the GT-30R series and GT-31S can be mounted. 03-00061B: Only the GT-30R series can be mounted. There is no difference based on the edition of IEC 61000-4-2.
[Option] Can the stand conversion adapter (for GT-31S), MODEL:03-00131A, be attached to PS-806?
Installation is possible. Please note that PS-806 was verified with models up to GT-30R. The center-of-gravity balance with the weight of GT-31S has not been verified, so precautions must be taken against tipping over.
[Option] Does the ESS-801 test environment come with a certificate of compliance with the IEC standard?
There is no certificate, but the instruction manual states "IEC61000-4-2 standard compliant."
[Option] Please tell me the material of the probe stand MODEL: 03-00108A.
The metal material of the probe stand is SUS303 (stainless steel). The material of the white handle section (gun holder) is engineering plastic POM (polyacetal resin).
[Tester] When the electrostatic tester (ESS-PS1) is used while connected to AC, is the battery inside the tester charged at the same time?
Yes, it is charged.
[Tester] What is the cable length between the discharge gun (GT-31S) and the electrostatic tester (ESS-PS1)?
The cable length between the discharge gun (GT-31S) and the electrostatic tester (ESS-PS1) varies by individual unit, but is approximately 2m. The same applies between the discharge gun (GT-30R) and the electrostatic tester (ESS-S3011A)..
[Tester] Two pieces of version information are displayed on the screen immediately after ESS-S3011A is powered on. What does each represent?
The value at the lower left of the screen is the firmware version, and the value at the right is the screen version.
[Tester] For the CHECK1 high-voltage output confirmation in the pre-check function of ESS-S3011A, what range must the value fall within for Pass to be displayed?
Pass is displayed if the value is within ±5% of the set voltage value. The voltage values are checked in the following order: +0.2, 2, 4, 6, 8, 15, 25, 30kV ⇒ -0.2, 2, 4, 6, 8, 15, 25, 30kV.
[Tester] What is the mechanism for detection and sensitivity setting of the discharge detection function in ESS-S3011A and ESS-B3011A?
Noise generated during discharge is received by the antenna circuit built into the discharge gun and detected through the filter in the tester main unit. The sensitivity is changed by switching the filter circuit, but there is no value that can be ...
[Main Unit] Is it acceptable to perform testing while ESS-PS1 is charging?
There is no problem. For measurements under “AC adapter connected,” measurement is performed while charging.
[Tester] When the cable of the GT-30RA discharge gun is draped over the ground plane, discharge detection may not work. Why?
The discharge detection function itself does not necessarily detect every discharge. If the discharge detection function works when the cable is kept away from the ground plane, please use it in that manner. Please understand that the IEC standard ...
[Tester] What kind of diagnostics are performed by the pre-check function of ESS-S3011A?
Please refer to the attached file.
[Optional item] What are the material, dimensions, mass, and load capacity of the insulating support table (03-00024A)?
The material is wood, and the dimensions, mass, and load capacity are as follows. Dimensions: W1200 × D1200 × H1000mm Mass: Approx. 22kg Load capacity: Approx. 500kg
[Optional item] What are the material, dimensions, and mass of the ground plane (03-00007A)?
The material is aluminum, and the dimensions and mass are as follows. Dimensions: (W) 1800 × (D) 1000 × (t) 1.5mm Mass: Approx. 7.2kg (1 sheet) * 03-00007A is supplied as a set of 3 sheets
[Optional item] The discharge gun extension cable (05-00047B) is outside the scope of the IEC 61000-4-2 standard, but does extending it by 3m affect the waveform?
No particular change is observed in the first peak of the current waveform, but a slight change has been confirmed in the second peak portion. However, no change large enough to conflict with the inspection criteria has been confirmed. Please note ...
[Optional item] What is the center adapter supplied with the vertical coupling plane (03-00005A)?
It is an adapter used to fix and contact the discharge tip (conical type) attached to the tip of the discharge gun to the horizontal coupling plane. This center adapter is a maintenance part. If it is lost or damaged, please contact our Customer ...
[Optional item] Regarding the discharge resistor cable (05-00054B), please explain why a resistor is included.
1. By inserting a resistor, it is possible to prevent charge from flowing into the cable all at once and to maintain electromagnetic field radiation. Specifically, it serves to let the charge flow slowly into the cable over a period of several ...
[Optional item] Why does the discharge resistor cable have resistors at both ends?
If the resistor is located in the middle, the cable itself may become an antenna source and generate radiated noise. By placing resistors at both ends, the cable itself does not become an antenna source, preventing radiated noise from the cable.
[Optional item] Regarding the discharge resistor cable (05-00054B), the terminal positions differ between the square-case side and the conical-case side (the square case is nearby, and the conical case is about 20mm away). When attaching it to the table (
Either side may be attached to the table (vertical coupling plane) or the floor surface (GND). * The reason why the terminal positions differ between the square-case side and the conical-case side (the square case is nearby, and the conical case is ...
[Optional Accessories] I am using a discharge gun with a model number starting with TC. Can I attach the discharge tips 12-00007A/12-00008A/12-00009A?
The discharge tips 12-00007A/12-00008A/12-00009A can only be attached to discharge guns with model numbers starting with GT, so they cannot be attached to discharge guns starting with TC.
[Optional item] What is the intended use of the automatic charge removal probe (01-00013A)?
In ESD testing of non-grounded equipment that has no ground path, reliable charge removal is required after each application. Therefore, although this is not a standards-compliant product, we prepared it so that work can be performed more efficiently ...
[Optional item] Can the ESD tester current target calibration set (06-00068B) continue to be used as a calibration jig for the current waveform target (06-00094A) for ESD tester verification?
It can be used.
[Optional item] Is there a maximum voltage limit for the ESD micro-gap discharge tip (12-00010A)?
There is no specific limit. However, at high voltage (for example, 30 kV, etc.), wear (deterioration) may occur more quickly.
[Option] With the infrared remote controller (13-00004A)*, it is no longer possible to change test conditions other than IEC mode. How can this be unlocked?
The remote controller has a function that can LOCK/UNLOCK test conditions other than IEC mode. To unlock it, assign [LOCK/UNLOCK] to one of the user-defined keys [F1] to [F4] on the infrared remote controller and press that button. Incidentally, ...
[Tester] Are the main unit ground of the electrostatic discharge simulator and the return cable of the discharge gun at the same potential?
Because a ferrite core is inserted between the main unit ground and the return cable, they are separated at high frequencies. However, they are at the same potential for DC.
[Option] What is the surface resistance value of conductive mat 03-00055A for ISO10605?
The surface resistance value of the conductive mat (green surface) is 10^7 to 10^9 [Ω/sq], in accordance with the standard value of ISO 10605.
[Option] About discharge tip 12-00010A
Q. Details A gap discharge test was performed using discharge tip 12-00010A with CR unit: 0Ω-500pF. 1) The discharge tip (gap section) has become blackened. Is it acceptable to continue using it as is? 2) When using discharge tip 12-00010A with CR ...
How does conductive mat MODEL: 03-00055A change over time?
This is our view, but the surface resistance value changes due to aging. Also, as the surface resistance value increases during use, the product reaches the end of its service life.
[Optional item] What is the size of the crimp terminal on discharge resistance cable 05-00054B?
It is 4.3Φ. The specification is 5.5-4; 5.5 indicates the thickness of the wire that can be crimped, and 4 indicates the screw size.
No spark discharge occurs even when the discharge gun trigger of the electrostatic discharge simulator is pulled. Is this a malfunction?
Before judging it to be a malfunction, check the trigger setting of the electrostatic discharge simulator main unit. * For details, please refer to the instruction manual for each model. Representative electrostatic discharge simulators [ESS-200AX / ...
[Tester] Regarding the setting of the application repetition cycle for electrostatic discharge testing, the main unit can be set for a minimum test setting of 0.05 s. Is a 0.05 s test also possible when using a 500 pF-0Ω CR unit?
When using a 500 pF-0Ω CR unit, the minimum is 0.2 s. The recommended minimum setting for the repetition cycle depends on the constants of the CR unit. The setting itself is possible, but sufficient charging cannot be performed, so the specified ...
[Tester] What is the supply voltage of the power cable supplied as standard?
The power cable supplied as standard is for AC100 to 240V. Please connect the power cable to a power outlet equipped with a protective earth terminal.
[Tester] How should the fuse of the electrostatic discharge simulator be replaced?
There is a fuse holder in the AC inlet on the back of the electrostatic discharge simulator, and customers can replace it themselves. If the recommended fuse is difficult to obtain, please contact our Customer Service Center.
[Tester] We own an ESS-625S and would like to perform evaluation equivalent to IEC 61000-4-2. Is this possible?
The ESS-625S was developed before the IEC standard was established, so it is not compatible.
[Tester] We are using two sets of ESS-S3011A and GT-30RA. During air discharge, there is a difference of 1 to 2 seconds after application until the trigger can be pulled and charging is possible. Why is this?
This is considered to be due to the radiation level mode setting. When set to special mode (EXTRA), it takes longer than in standard mode (NORMAL). Please note that special mode (EXTRA) is set at the time of product shipment.
[Main Unit] What is the approximate service life of the battery used in the ESS-PS1?
At an ambient temperature of 25°C, when one cycle consists of full charge → discharge → full charge (100% → 0% → 100%), ? after 300 cycles, the charging capacity will be 75% of the original capacity. The battery alone can also be replaced by CSC.
[Optional item] Can we assemble the test environment (table type / floor-standing type) ourselves?
No special tools are required, and customers can assemble it themselves.
[Optional item] What are the material, dimensions, weight, and load capacity of test table 03-00039A?
The material is wood, and the dimensions, weight, and load capacity are as follows. Dimensions: (W) 1600 × (D) 800 × (H) 800 mm Weight: Approx. 22 kg Load capacity: Approx. 100 kg
Is it possible to purchase the internal battery for the ESS-PS1 electrostatic discharge simulator?
Customers cannot replace it themselves, so if you would like to replace a spare battery, please contact our Customer Service Center.
If the ESS-PS1 battery is fully charged, about how many hours will the battery last? Or about how many charge/discharge cycles of the discharge gun are possible?
Please consider approximately 8 hours as a guideline for continuous operating time when fully charged. However, including the number of discharges, this varies depending on the usage method, so it cannot be stated definitively.
Next page