Product Specifications (including optional items)
[Option] Does the insulation support (03-00066A) comply with ISO 10605 Ed.2?
It complies with ISO 10605 Ed.2. However, it does not comply with Ed.3; in Ed.3, it has been replaced by the insulation block (03-00054A).
Regarding the radiation level modes of ESS-B3011 and ESS-S3011, EXTRA is described as producing less radiation than NORMAL. However, some EUTs do not malfunction in NORMAL but do malfunction in EXTRA. Why does this occur?
This may occur if the charge/discharge capacitor does not discharge sufficiently during application and some charging voltage remains in it. In EXTRA, the high-voltage power supply is turned OFF (0V) when the relay is OFF, reducing the potential ...
[Option] Is there a way to extend the cable and return cable of the GT-30R Series discharge gun?
Extension cable "05-00047B" can be used for the connection cable to the discharge gun (gray cable). The return cable can also be custom-made to extend it to 3m. In that case, your discharge gun must be returned to us. If you do not require a single ...
[Option] What is the estimated life of the high-voltage relay in the GT-30R Series discharge gun?
The estimated life of the high-voltage relay in the discharge gun varies depending on conditions such as the charge/discharge capacitor and discharge resistor values, output voltage, and repetition interval. When 30KV is output once per second using ...
Please tell me the dimensions of discharge tips 12-00007A/8A/9A.
12-00007A/8A conform to the specified dimensions of IEC61000-4-2. The tip angle of our contact discharge electrode 12-00007A is 40°. For our spherical air discharge electrode 12-00009A, which can be used for air discharge of 15kV or higher as ...
What is the material of the discharge resistor cable "05-00054B" and ground cable (for ISO standards) "05-00104A"?
The cable material (other than sheath and resistor) is tin-plated soft copper wire.
Can the discharge gun holder of the ESS-PS1 be connected to the tester body like the ESS-S3011A?
The gun holder cannot be connected to the tester body.
[Option] Does the ESD voltage meter MODEL:18-00086B require periodic calibration?
Voltage meters generally require periodic calibration.
[Option] What is the withstand voltage rating of the discharge resistance cable <05-00054B>?
No specific specification has been established. However, it can be used within the scope of IEC61000-4-2 standard testing, so applying voltages up to 15kV with a 150pF/330Ω CR unit presents no issue.
[Test Equipment] Is aging of the test equipment required before performing an ESD test?
Unless the climatic conditions for testing are specifically defined by the standard, they must be within the operating limits specified by the respective manufacturers for the EUT and test equipment.
[Test Equipment] How long is the battery operating time of the ESS-PS1?
As reference values, the operating time is approximately 3 hours at a test voltage of -30kV and 20 discharges per second, and approximately 8 hours at a test voltage of -8kV and 1 discharge per second.
[Option] If the EUT exceeds the dimensions of the ground plane, how should the size of the ground plane to be used be determined?
Our ground plane (03-00007A) is a set of three 1.8m × 1.0m plates. Under IEC61000-4-2, the ground plane must extend at least 0.5m beyond all sides of the EUT or horizontal coupling plane, so 3m is required: 2.0 + 0.5m (right side) + 0.5m (left side). ...
[Option] Is there any problem with using a commercially available interface instead of the 07-00022A USB optical interface?
For products other than those verified in-house, we cannot determine whether they can be used or guarantee their use.
[Optional Accessories] I am using a discharge gun with a model number starting with TC. Can I attach the discharge tips 12-00007A/12-00008A/12-00009A?
The discharge tips 12-00007A/12-00008A/12-00009A can only be attached to discharge guns with model numbers starting with GT, so they cannot be attached to discharge guns starting with TC.
[Optional Accessories] What screw size is used when attaching the discharge resistance cable 05-00054B?
M4 size (with washer). 2 pieces are required for the connection between the horizontal coupling plane and ground plane, and 2 pieces are required for the connection between the vertical coupling plane and ground plane. *4 pieces are included as ...
[Optional Accessories] What screw size is used when connecting ground planes 03-00007A?
M3 size (with washer), and 12 pieces are required for 3 plates. *12 pieces are included as standard at the time of shipment.
[Optional Accessories] What are the material, dimensions, and weight of the ground plane 03-00007A?
The material is aluminum, and the dimensions and weight are as follows. Dimensions: (W)1800 × (D)1000 × (t)1.5mm Weight: Approx. 7.2kg (1 piece) *03-00007A comes as a set of 3 pieces.
[Optional Accessories] What are the material, dimensions, weight, and load capacity of the insulation support stand 03-00024A?
The material is wood, and the dimensions, weight, and load capacity are as follows. Dimensions: (W)1200 × (D)1200 × (H)1000mm Weight: Approx. 22kg Load capacity: Approx. 500kg
[Optional Accessories] What are the material and dimensions of the insulation sheet 03-00004A?
The material is vinyl chloride, and the dimensions are as follows. Dimensions: (W)1450 × (D)650 × (t)0.5mm
[Optional Accessories] What are the material, dimensions, and weight of the horizontal coupling plane 03-00020A?
The material is aluminum, and the dimensions and weight are as follows. Dimensions: (W)1600 × (D)800 × (t)1.5mm Weight: Approx. 5.2kg
[Optional Accessories] What are the material, dimensions, weight, and load capacity of the test table 03-00039A?
The material is wood, and the dimensions, weight, and load capacity are as follows. Dimensions: (W)1600 × (D)800 × (H)800mm Weight: Approx. 22kg Load capacity: Approx. 100kg
[Optional Accessories] Can we assemble the test environment (table-type/floor-standing type) ourselves?
No special tools are required, and customers can assemble it themselves.
[Tester] Is there a warm-up time specification for the electrostatic discharge testers ESS-S3011A/B3011A?
There is no specific warm-up time specification.
[Tester] What is the difference between electrostatic discharge testers ESS-S3011A and ESS-B3011A?
ESS-S3011A is a programmable type tester equipped with three precheck functions, while ESS-B3011A is a basic type tester with reduced functions for easier testing. Both types use the same discharge gun.
[Tester] Please tell me about the outline specifications (features) of the electrostatic discharge tester.
It is a discharge gun type electrostatic discharge tester with a maximum output of 30kV that complies with IEC 61000-4-2 / ISO 10605 standards.
[Tester] Regarding the external trigger of ESS-S3011, how long after signal input is the output applied?
The external trigger is recognized in approximately 15 to 25 ms, and application starts after a mechanical contact (relay) delay of about 10 ms. (The gun trigger operates in the same way.)
[Main Unit] Q. Does the discharge current waveform of the GT-30RA/GT-30RB discharge gun change between EXTRA mode and NORMAL mode?
The discharge current waveform changes very little between EXTRA mode and NORMAL mode.