Is the TF-6503P maximum output current of 50 A 50 A per phase, or 50 A total for all phases combined?
For a star-connected transformer, “phase current = line current,” so it is 50 A per line.
About the data sheets for LANGER probes (What is the difference between the data sheet included with the product and the data sheet available on the web?)
They differ due to differences in measurement methods. ・Included data: measurement using a microstrip board (current measurement on a transmission line) ・Web data: measurement of a uniform electric field in a TEM cell
[Main Unit] At which part of the impulse noise simulator using semiconductor relays is the waveform guaranteed?
The waveform is guaranteed only at the PULSE OUT section. The waveform is not guaranteed at the CDN section.
[Option] Can a discharge module (CR for GT-31S) exceeding 1000 pF be manufactured?
It cannot be manufactured because the capacitor is too large to fit inside the discharge module.
[Tester] What are the weight and dimensions of the INS-S220/S420 impulse noise tester?
INS-S220: External dimensions W430×H249×D540 (mm) (excluding protrusions); mass: approx. 20 kg INS-S420: External dimensions W430×H349×D540 (mm) (excluding protrusions); mass: approx. 23 kg
[Tester] Are there consumable parts for the impulse noise tester?
The coaxial cable, high-voltage coaxial connectors (both inside and outside the chassis), and fuse are consumable parts. If the resistance value of the coaxial cable has dropped to DC 1000 V / 100 MΩ or less, the cable and connector need to be ...
[Tester] How should the fuse be replaced on the INS-S220/S420 impulse noise tester?
There is a fuse holder in the AC inlet on the rear of the impulse noise tester, and the customer can replace the fuse. If the recommended fuse is difficult to obtain, please contact our Customer Service Center.
[Test Equipment] What happens when EUT power capacity exceeding the rating is input?
If voltage and current exceeding the rating are input, it may cause damage to the tester or fire. CDN components or wiring inside the tester may disconnect due to heat, so please use within the rated specifications.
[Option] What is the material of the aluminum plate used for the ground plane?
A5052 is used.
[Tester] Is testing possible on a 3-phase 3-wire EUT using INS-S420 alone?
Testing is possible. Since the L, N, and PE terminals are all floating from the tester chassis, testing can be performed by connecting the power supply by treating L as L1, N as L2, and PE as L3. However, please note that the product specification ...
[Option] Can the connecting bracket used to connect INS-S420 and IJ-AT450 also be used in combination with INS-S220?
It can be used.
[Option][Tester] For 14-00062A, if the PC enters SLEEP mode during sequence operation with INS-S420+IJ-AT450, will the sequence complete?
When checked on a Win11 PC, even if the PC entered SLEEP mode, the test did not stop and ran through to the end of the sequence. * Depending on the OS version, the hard disk power may turn OFF in SLEEP mode, which could stop the test.
【Option】Can 15-00007A (CA-806) be used at 4kV?
15-00007A (CA-806) is specified for up to 2kV, so 4kV cannot be applied. Doing so may damage the equipment; please exercise caution. However, because the coupling ratio is 1/10, a 4kV setting is expected to result in 400V coupling. To couple 400V, ...
【Tester】When using the INS-AX2 series together with CA-805B, what termination resistance value should be set?
Set the termination resistance to o60.0Ω. When connected without an external termination resistor, termination is provided internally by the INS, resulting in o60.0Ω.
Is there a way to set more than 6 pulse width patterns when testing the INS-S series with remote software 14-00062A or 14-00069A? Only 5 patterns can be set in the "Multiple" tab.
If you want to perform tests with more than 6 patterns, this can be done using sequence testing. An example of the setup procedure is as follows: ①Create and save files with pulse widths (e.g., 50, 100, 200ns) in manual test ②Create and save files ...
[Tester] Please tell me about the general specifications (features) of impulse noise testers INS-S220/S420.
It can output fast-rising square-wave impulse noise with a maximum voltage of 2 kV or 4 kV at 50Ω termination and a rise time of 3 ns or less. The pulse width can be set from 50 ns to 1000 ns, and the pulse repetition cycle can be set to AC line ...
Q. [Tester] What is the difference between impulse noise testers INS-S220 and INS-S420?
The difference is in the pulse output voltage: INS-S220 has a maximum of 2 kV, and INS-S420 has a maximum of 4 kV. However, the EUT power supply capacity is the same for both: single-phase AC240V /16A DC125V / 16A MAX. For INS-S220, the configurable ...
[Test Equipment] Can impulse noise testers INS-S220/S420 perform all-phase application or simultaneous multi-phase application?
Fast transient/burst testers can perform all-phase application and simultaneous multi-phase application, but impulse noise testers cannot.
[Tester] Can triangular-wave testing be performed with INS-S220/S420?
With the older models (INS-4020/4040), it could be performed by installing the optional triangular-wave generation unit, but triangular-wave testing cannot be performed with INS-S220/S420.
[Tester] Please explain EXT TRIG mode on the impulse noise simulator INS-S220. ① How are pulses output when an external signal is input? ② The instruction manual states, 'Set the synchronization signal period to 10 ms or more, and input a negative-polarit
① When an external signal is input, one pulse is applied in synchronization with it. Example: If external signals are input 5 times at 1-second intervals, a total of 5 pulses are applied, one every second. ② There is an error in the INS-S220 ...
[Test Equipment] Is there a specified warm-up time for impulse noise testers INS-S220/S420?
There is no specified warm-up time.
[Tester] Is 24-hour continuous testing possible in tests using INS-S220/S420?
Basically, INS-S220/S420 are not testers designed for 24-hour continuous operation.
[Tester] What is the power consumption of the impulse noise simulators INS-S220 /S420?
INS-S220 is approximately 110VA, and INS-S420 is approximately 215VA.
[Optional item] What is a coupling adapter?
It is a fixture that couples noise without directly connecting the pulses generated by the impulse noise simulator to signal lines, power lines, etc.
[Optional item] What is a radiation probe?
This is a probe used with an impulse noise simulator or fast transient/burst tester as the pulse generator, to apply a strong electric field to products, printed circuit boards, etc., for the purpose of identifying malfunction locations.
[Optional item] Do the characteristics change depending on the diameter size of the radiation probe?
The magnetic field strength near the loop does not change regardless of size. However, because the magnetic field strength at the center of the loop is inversely proportional to distance, Smaller diameter ⇒ the magnetic field at the center becomes ...
[Optional item] What is the difference between CA-805B and 15-00007A (CA-806)?
Because CA-805B uses a capacitive coupling method (electric field), it is an effective coupling adapter for high-impedance signal lines. Because 15-00007A (CA-806) uses an inductive coupling method (magnetic field), testing can be expected to be less ...
[Tester] Operations using EXT TRIG on INS-4020/4040 include EXTERNAL TRIG mode operation (Instruction Manual p.36) and remote operation (same manual p.51). Is there any difference between the two?
EXTERNAL TRIG mode operation (p.36): When operating by turning the EXT TRG button ON after power startup, start/stop operation is enabled. During test start, when a Low level is detected from the external synchronization signal input connector (BNC), ...
[Optional item] I would like to use H2-B with an impulse noise simulator. Are there any precautions?
When using H2-B with an impulse noise simulator, keep the maximum set voltage to 1kV and the pulse width not exceeding 50ns.
[Option] Can a 4kV test be performed with the 15-00007A (CA-806)?
The 15-00007A (CA-806) is rated up to 2kV and cannot be used to apply 4kV. Because the ratio is 1/10, a 2kV setting is expected to produce 200V of superimposed voltage. A 400V (200V × 2) test can be performed by winding the line under test twice ...
[Optional item] Please tell me how to select the coupling capacitor used with the noise injection probe 01-00034A.
Basically, the larger the coupling capacitor capacitance, the more effectively noise can be applied. However, if the capacitance is large, the impedance becomes smaller, so it may affect circuit operation. For this reason, it is important to select a ...
[Optional item] I would like to check the characteristics (insertion loss) of the waveform observation attenuator 00-00017A, and I need an adapter that converts the high-voltage HN connector to an N connector (J). Can it be purchased as a general-purpose
The high-voltage HN connector is not a special item, so a general-purpose product is acceptable.
[Test Equipment] What type of connector is on the included coaxial cable?
There are coaxial connectors with similar appearances, but this is a high-voltage coaxial connector "NMHV" uniquely developed by our company for use with testers where output pulse voltage exceeds 3kV. Please be sure to use the included coaxial cable ...
[Test Equipment] What happens when EUT power capacity exceeding the rating is input?
If voltage and current exceeding the rating are input, it may cause damage to the tester or fire. CDN components or wiring inside the tester may disconnect due to heat, so please use within the rated specifications.
[Test Equipment] What is the power consumption of impulse noise testers INS-S220/S420?
INS-S220 is approximately 110VA, and INS-S420 is approximately 215VA.
[Test Equipment] Is there a specified warm-up time for impulse noise testers INS-S220/S420?
There is no specified warm-up time.
[Test Equipment] Can impulse noise testers INS-S220/S420 perform all-phase application or simultaneous multi-phase application?
Fast transient/burst testers can perform all-phase application and simultaneous multi-phase application, but impulse noise testers cannot.
[Test Equipment] What is the difference between impulse noise testers INS-S220 and INS-S420?
There is a difference in pulse output voltage: INS-S220 has a maximum of 2kV, and INS-S420 has a maximum of 4kV, but the EUT power capacity is single-phase AC240V/16A DC125V/16A MAX for both. For INS-S220, the settable ranges for pulse width and ...
[Test Equipment] Please tell me about the general specifications (features) of impulse noise testers.
It can output fast square wave impulse noise with a maximum voltage of 2kV or 4kV at 50Ω termination and a rise time of 3ns or less. Pulse width ranges from 50ns to 1000ns, pulse repetition period can be AC line (50Hz/60Hz) synchronized or Variable ...
Q. Do INS-4020/4040/S220/S420/S100 use switching or linear power supplies?
They all use switching power supplies.