Is there a way to set more than 6 pulse width patterns when testing the INS-S series with remote software 14-00062A or 14-00069A? Only 5 patterns can be set in the "Multiple" tab.

Is there a way to set more than 6 pulse width patterns when testing the INS-S series with remote software 14-00062A or 14-00069A? Only 5 patterns can be set in the "Multiple" tab.

If you want to perform tests with more than 6 patterns, this can be done using sequence testing.
An example of the setup procedure is as follows:
①Create and save files with pulse widths (e.g., 50, 100, 200ns) in manual test
②Create and save files with pulse widths (e.g., 400, 800, 1000ns) in manual test
③Select and save the files from ① and ② in sequence test