Because CA-805B uses a capacitive coupling method (electric field), it is an effective coupling adapter for high-impedance signal lines.
Because 15-00007A (CA-806) uses an inductive coupling method (magnetic field), testing can be expected to be less affected by the impedance of the signal line.