Basically, the larger the coupling capacitor capacitance, the more effectively noise can be applied.
However, if the capacitance is large, the impedance becomes smaller, so it may affect circuit operation.
For this reason, it is important to select a large capacitance within a range that does not affect circuit operation.
Therefore, before applying noise, touch the injection probe to the board and confirm that the board functions before performing the test, so we recommend preparing multiple coupling capacitors.
In order to sufficiently supply the energy of impulse noise to the EUT circuit, a larger capacitor capacitance is advantageous.
However, the dynamic output impedance of the impulse noise simulator and EFT/B tester is 50Ω.
Assuming a case where a 1MHz frequency signal is being transmitted through the signal pattern of the printed circuit board to be tested, if a 500pF coupling capacitor is used, the impedance of the coupling capacitor due to the 1MHz signal is approximately 318Ω when substituted into Z=1/(2πfC).
Adding the 50Ω output impedance of the impulse noise simulator to this results in approximately 370Ω of resistance connected between the signal line and GND.
If this resistance component reduces the voltage amplitude of the signal line, the board may no longer function.
To avoid this, select the coupling capacitor. Before applying noise, touch the injection probe to the board and confirm that the board functions before performing the test.
The higher the signal frequency becomes, the more pronounced this phenomenon becomes.