Test method
Why is a wooden table recommended for impulse noise testing?
For benchtop impulse noise testing, instruction manuals and similar documents show a GND plane placed on a wooden table. However, if the test can be performed on a metal surface with a stable electrical potential, there is no problem using a table ...
For signal-line testing, are there any recommended settings for the timing of impulse noise application?
For signal-line testing, set the application period of the test using Variable. However, the shortest Variable setting is not always the most severe, so we recommend trying various application periods. For example, the shortest period of the INS-4040 ...
Place an insulating support (height 0.1 m) on the ground plane, and place the EUT on top of it for testing.
When using a coupling adapter, do not take the EUT power supply through the impulse noise tester; take it independently from the primary side. Also, when testing power lines, do not connect the coupling adapter to the impulse noise tester.
How should equipment be arranged for a large EUT that cannot be placed on the test table?
Place an insulating support (height 0.1 m) on the ground plane, and place the EUT on top of it for testing.
When the impulse noise tester and the ground plane are connected by an SG cable using the shortest possible connection, is it acceptable not to place the entire tester on the ground plane?
The entire tester must be placed on the ground plane. The noise output from the tester ultimately returns to the SG inside the tester enclosure, but impulse noise contains many high-frequency components, so the ground plane and tester enclosure ...
What should I do if grounding is difficult with the included drive power cable?
There is an FG terminal on the back of the impulse noise tester. Only when grounding is difficult, connect this terminal to the protective earth terminal of the test room using appropriate wire material. However, do not connect directly to the ground ...
Are there specifications for the SG cable that connects to the ground plane?
The included SG cable is connected to the ground plane for testing, but if connection is not possible, connect to the ground plane using wire material that is as thick and short as possible (braided wire of 3.5mm? or more is recommended).
The EUT is a power supply. If the power supply (EUT) is connected to the EUT LINE OUTPUT of the impulse noise simulator, and a load is connected to the EUT LINE INPUT side while power is supplied during testing, will the tester fail?
There will be no failure as long as the input rating specifications of INS are not exceeded.
On INS-S420, the EUT line input terminals are the three terminals L, N, and PE. Is it possible to test application to a 3-phase 200V line without using a superimposition unit, such as by routing one of the three-phase lines externally?
If one of the three-phase lines is routed externally and the voltage between the phases being input above is AC240V or less, INS-S420 will not fail. However, there is a possibility that the test results may be affected depending on whether one of the ...
Is connecting the short plug required for the 01-00006A (radiation probe) test?
The basic noise return path is the core conductor of the coaxial cable → radiation probe → shield of the coaxial cable. Because it is not a loop that passes through the ground plane or EUT, the short plug is not required; however, coupling to the ...
CA-805B has terminals at both ends, and noise is injected from them, but only one side has a GND terminal. Is there any difference in the coupled noise when the noise input is applied from the terminal opposite the GND terminal side compared with when it
The coupled noise changes very little whether it is applied from the GND terminal side or the opposite side. However, the side connected to pulse out tends to have more coupled noise. (In practice, the above tendency may vary depending on cable ...
If a ferrite core is installed between the primary side of the impulse noise simulator and the isolation transformer to prevent the effects of external electromagnetic waves (where the wiring acts as an antenna), can the waveform change?
If installed between L-N, it acts as a common-mode noise filter, and because the normal-mode output impedance decreases, depending on the connected load, a phenomenon may occur in which the rise time of the impulse noise waveform becomes slower.
Can impulse noise testing substitute for fast transient/burst testing?
Testing cannot be substituted.
Is grounding work required when conducting tests?
Grounding work based on the Technical Standards for Electrical Facilities is broadly classified into four types, A through D, but grounding work is not required when conducting tests. However, please connect the power cord to a power outlet equipped ...
Can tabletop equipment EUT be tested on a ground plane installed on the floor?
Testing may be conducted.
How should radiation probes be used?
Radiation probes with large loops provide uniform magnetic fields overall, while radiation probes with small loops provide strong electric fields locally. Select a radiation probe considering EUT size and other factors, and conduct testing.
How should coupling adapters be used?
Select a coupling adapter with the optimal coupling method (capacitive or inductive) based on the impedance of signal lines and other cables to which noise is to be coupled, and conduct testing by clamping it onto the target cable. As a general ...
Is an isolation transformer required for impulse noise testing?
It is required when connecting AC power for EUT to the tester. An isolation transformer (noise canceler transformer) is essential to prevent electric shock and AC line earth leakage circuit breaker activation when applying to the AC line.
What are the test modes (common mode/normal mode) in impulse noise testing?
Common mode testing is a power line-to-ground test based on ground (e.g., applied to L-phase with ground as reference), while normal mode testing is a test between power lines (e.g., applied to L-phase with N-phase as reference). Testing in both ...
Do differences in equipment layout (test environment) cause variations in test results?
Equipment layout (test environment) for impulse noise testing varied among manufacturers, so industry association guidelines were revised with reference to equipment layout examples from IEC 61000-4-4 (fast transient/burst testing). Test results may ...
I would like to know an overview of impulse noise testing.
Equipment is arranged according to the equipment layout examples described in industry association guidelines, and testing is conducted according to test conditions (common mode/normal mode testing for AC/DC driven equipment, signal line testing ...
Is an isolation transformer also required for the drive power cable of an impulse noise tester?
It is not required. An isolation transformer is required when connecting the AC power supply for the EUT to the tester.