For signal-line testing, are there any recommended settings for the timing of impulse noise application?

For signal-line testing, are there any recommended settings for the timing of impulse noise application?

For signal-line testing, set the application period of the test using Variable.
However, the shortest Variable setting is not always the most severe, so we recommend trying various application periods.
For example, the shortest period of the INS-4040 is 16 ms.