[Test Equipment] Does the LSS-F03 series comply with IEC 60664? (Dielectric withstand test)

[Test Equipment] Does the LSS-F03 series comply with IEC 60664? (Dielectric withstand test)

It does not comply because the waveform interpretation and peak voltage tolerance are different.
IEC 60664: Peak voltage tolerance is ±3%
IEC 61000-4-5: LSS-F03 has a specification of ±10% relative to the set voltage
IEC 60664: Uses IEC61000-4-5 Ed.2, not Ed.3.
⇒Due to the difference in interpretation between Ed.3 and Ed.2, the half-value width and rise time differ by about 1%, so waveform cannot be guaranteed.