Please tell me about the cable length and type for the noise test described in JIS E5006.

Please tell me about the cable length and type for the noise test described in JIS E5006.

As a rule, the cable type should basically be the same as the one actually used when installed or built into the equipment.
If a power cable is supplied or built into the equipment, use it as is.

If it is long, fold it and secure it with tape or similar so that it does not form a loop.

As a rule, cables are placed on an insulating support at a height of 0.1 m. Secure them with tape or similar so that the height remains constant.

If the plug at the end does not fit the tester, cutting it and connecting it is best; however, if that is not permitted, use a conversion plug and keep the condition as close as possible to normal installation.

For high-frequency tests (impulse, EFT/B), the distance between the tester and the EUT should generally be within 0.5 m to 1 m. (If it is long, the noise attenuates.)

The international standard IEC61000-4-4 (EFT/B) specifies the distance between devices, not the cable length.
This resolves issues such as the cable not reaching 0.5 m due to differences in outlet height.

Because data shows that, if the distance is constant, the effect of different cable lengths is small, the standard specifies the device-to-device distance.