The lifespan of gas arresters varies greatly depending on the set voltage, so we cannot provide a uniform lifespan.
Regardless of the number of applications, the arrester needs to be replaced when it no longer emits light when a surge is applied.
The following lifespans are provided for reference.
- Approximate lifespan when applying a 1.2/50μs waveform at 4kV to LSS-INJ6401SIG: approximately 30,000 times
- Approximate lifespan when applying a 10/700μs waveform at 4kV to LSS-6330TEL: approximately 4,000 times
Another factor that reduces lifespan is degradation caused by the arrester remaining ON due to overvoltage input of the signal.