[Optional Accessory] Is there a method to conduct testing while communicating via RS-485 (balanced line) using LSS-INJ6401 or Telecom CDN?

[Optional Accessory] Is there a method to conduct testing while communicating via RS-485 (balanced line) using LSS-INJ6401 or Telecom CDN?

Testing RS-485 while communicating via LSS-INJ6401 or Telecom CDN is difficult.

LSS-INJ6401 is designed for unbalanced line testing, and since the decoupling L is not wound in common mode, differential signals are unlikely to pass through.
The Telecom superposition section is designed for telephone lines, so the expected frequency is several kbps.

Since the decoupling L is wound in common mode with two wires each, it becomes impedance for communication.
If the voltage is too low or the impedance on the EUT side is low, voltage drop may occur and communication may become impossible.