①CAT5E UTP (unshielded) ②CAT5E STP (shielded) ③CAT6 UTP (unshielded) ④CAT6 STP (shielded)
?
?
Since CAT5E and CAT6 have a maximum communication speed of 1000Mbps, testing with F-130814-1004 is possible.
①CAT5E UTP (unshielded) and ③CAT6 UTP (unshielded) can be tested without any issues.
However, ②CAT5E STP (shielded) and ④CAT6 STP (shielded) are both shielded cables, so the test method differs from the original IEC61000-4-5 test method.
Also, when using F-130814-1004, the CDN is inserted between the EUT and AE, which temporarily breaks the shield continuity. Since this differs from the actual usage environment where shielded cables are used,
although application using CDN is possible, it cannot be considered appropriate as a test.
?