Is there a method to conduct RS-485 (balanced line) testing while communicating using LSS-INJ6401 or Telecom CDN?

Is there a method to conduct RS-485 (balanced line) testing while communicating using LSS-INJ6401 or Telecom CDN?

It is difficult to conduct RS-485 testing while communicating using LSS-INJ6401 or Telecom CDN.
LSS-INJ6401 is for asymmetrical line testing, and since the decoupling L is not wound in common mode, differential signals are not expected to pass through.
The Telecom superimposition section assumes telephone lines, so the expected frequency is several kbps.
Since the decoupling L is wound in common mode with 2 wires each, it becomes impedance for communication,
so if the voltage is too low or the EUT side impedance is low, voltage drop may occur and communication may become impossible.
(Telephone line 600Ω, RS-485 120Ω recommended)