In IEC61000-4-5 Ed.2, the coupling method was to be determined by higher-level standards or product specifications.
However, as an announcement, there is a statement that capacitor coupling is the preferred method, and arrester coupling should be used when capacitor coupling is not possible (standard document 6.3.2.1, 6.3.2.3).
In Ed3, the description of priority between capacitor and arrester has been removed, but the influence of noise when using GDT (arrester) is mentioned.
With our LSS-INJ6401SIG, the waveform is clean during capacitor coupling, but switch noise appears at the wavefront during arrester coupling.
Although there is no description of priority in the standards, it is considered desirable to use arrester coupling when communication is not possible with capacitor coupling.