Popular Articles
What are contact discharge and air discharge?
Contact discharge applies by contacting the metal parts of the EUT, and air discharge applies by approaching the non-metal parts of the EUT. These are differences in operation modes. Contact discharge uses a conical discharge tip, and air discharge ...
What are direct application (direct discharge) and indirect application (indirect discharge)?
Direct application (direct discharge) is a method of applying contact discharge or air discharge to the EUT, and indirect application (indirect discharge) is a method of applying by contacting a conical discharge tip to a horizontal coupling plate or ...
Since it is difficult to hold the discharge gun grip with one hand for a long time, is it okay to hold other parts of the discharge gun during testing?
Please conduct the test by holding the grip with one hand. If you support other parts of the discharge gun body or discharge cup with your other hand other than the grip, the output waveform may change (Ip increase) due to human influence ...
Is it okay to use rubber gloves to prevent electric shock?
You may use rubber gloves. In IEC 61000-4-2, which is the standard for electrostatic testing, waveform verification is performed without human intervention, so during testing, either bare hands or gloves are acceptable. There is no specification for ...
Please tell me about the test voltage when conducting air discharge testing under IEC 61000-4-2 Ed.2.
In the case of air discharge testing, the standard specifies that the designated test level and all lower levels should be performed. The reason is that at low levels (e.g., 2kV) and high levels (e.g., 8kV), the discharge destination of the air ...